Back to Home

Temperature & Humidity Sensors (Probes, Radiation Shields and Displays)

Temperature and relative humidity sensors measure air temperature and humidity, two of the most important measurements in any weather station. Our range includes R.M. Young relative humidity/temperature probes with 4-20 mA or 0-1 VDC outputs, platinum RTD and thermistor temperature sensors, Gill multi-plate radiation shields that protect the sensors from solar radiation and precipitation, and the Temp Tracker temperature and humidity display.


Model 41372L Relative humidity/temperature probe.

R.M. Young
The Model 41372L Relative Humidity/Temperature Probe combines a high accuracy Vaisala Intercap capacitance type humidity sensor and a 1000 ohm platinum RTD temperature sensor in one probe. The probe is easily installed in R.M. Young multi-plate and aspirated shields. This probe has 4-20 mA outputs for temperature and RH.
Sensor typeTemperature: 1000 ohm platinum RTD
Humidity: Vaisala Intercap capacitance type
Measuring rangeTemperature: -50 to 50°C (calibrated)
Humidity: 0-100% RH
AccuracyTemperature at 0°C: ±0.3°C
Humidity at 20°C: 3% from 10 to 90% RH and 4% from 1 to 10 and 90 to 100% RH
Time constantTemperature: 42 seconds with Model 43408 aspirated shield
Humidity: 15 seconds
StabilityHumidity: better than ±2% over 2 years
Operating temperatureHumidity: -10 to 60°C (accuracy reduced below -10°C)
OutputTemperature: 4-20 mA
Humidity: 4-20 mA
Power requiredTemperature: 12-30 VDC, 20 mA
Humidity: 12-30 VDC, 40 mA
41372L photo 1
41372L photo 2

Model 41372V Relative humidity/temperature probe.

R.M. Young
The Model 41372V Relative Humidity/Temperature Probe combines a high accuracy Vaisala Intercap capacitance type humidity sensor and a 1000 ohm platinum RTD temperature sensor in one probe. The probe is easily installed in R.M. Young multi-plate and aspirated shields. This probe has 0-1 VDC outputs for temperature and RH.
Sensor typeTemperature: 1000 ohm platinum RTD
Humidity: Vaisala Intercap capacitance type
Measuring rangeTemperature: -50 to 50°C (calibrated)
Humidity: 0-100% RH
AccuracyTemperature at 0°C: ±0.3°C
Humidity at 20°C: 3% from 10 to 90% RH and 4% from 1 to 10 and 90 to 100% RH
Time constantTemperature: 42 seconds with Model 43408 aspirated shield
Humidity: 15 seconds
StabilityHumidity: better than ±2% over 2 years
Operating temperatureHumidity: -10 to 60°C (accuracy reduced below -10°C)
OutputTemperature: 0-1 VDC
Humidity: 0-1 VDC
Power requiredTemperature: 8-24 VDC, 5 mA
Humidity: 8-24 VDC, 9 mA
41372V photo

Model 41382L Relative humidity/temperature probe.

R.M. Young
The Model 41382L Relative Humidity/Temperature Probe combines a high accuracy Rotronic Hygromer™ capacitance type humidity sensor and a 1000 ohm platinum RTD temperature sensor in one probe. The probe is easily installed in R.M. Young multi-plate and aspirated shields. This probe has 4-20 mA outputs for temperature and RH.
Sensor typeTemperature: 1000 ohm platinum RTD
Humidity: Rotronic Hygromer™ capacitance type
Measuring rangeTemperature: -50 to 50°C (calibrated)
Humidity: 0-100% RH
AccuracyTemperature at 0°C: ±0.3°C
Humidity at 20°C: ±2%
Time constantTemperature: 42 seconds with Model 43408 aspirated shield
Humidity: 10 seconds without filter
StabilityHumidity: better than ±1% over 1 year
Operating temperaturen/a
OutputTemperature: 4-20 mA
Humidity: 4-20 mA
Power requiredTemperature: 10-28 VDC, 20 mA
Humidity: 10-28 VDC, 40 mA
41382L photo

Model 41382V Relative humidity/temperature probe.

R.M. Young
The Model 41382V Relative Humidity/Temperature Probe combines a high accuracy Rotronic Hygromer™ capacitance type humidity sensor and a 1000 ohm platinum RTD temperature sensor in one probe. The probe is easily installed in R.M. Young multi-plate and aspirated shields. This probe has 0-1 VDC outputs for temperature and RH.
Sensor typeTemperature: 1000 ohm platinum RTD
Humidity: Rotronic Hygromer™ capacitance type
Measuring rangeTemperature: -50 to 50°C (calibrated)
Humidity: 0-100% RH
AccuracyTemperature at 0°C: ±0.3°C
Humidity at 20°C: ±2%
Time constantTemperature: 42 seconds with Model 43408 aspirated shield
Humidity: 10 seconds without filter
StabilityHumidity: better than ±1% over 1 year
Operating temperaturen/a
OutputTemperature: 0-1 VDC
Humidity: 0-1 VDC
Power requiredTemperature: 10-28 VDC, 5 mA
Humidity: 10-28 VDC, 8 mA
41382V photo

Model 41342L Temperature probe.

R.M. Young
The Model 41342L Temperature Probe consists of a 1000 ohm platinum RTD temperature sensor. The probe is easily installed in R.M. Young multi-plate and aspirated shields. This probe has a 4-20 mA output.
Sensor type1000 ohm platinum RTD
Measuring range-50 to 50°C (calibrated)
Accuracy±0.3°C at 0°C
Time constant42 seconds with Model 43408 aspirated shield
Output4-20 mA
Power required12-30 VDC, 20 mA
41342L photo

Model 41342V Temperature probe.

R.M. Young
The Model 41342V Temperature Probe consists of a 1000 ohm platinum RTD temperature sensor. The probe is easily installed in R.M. Young multi-plate and aspirated shields. This probe has a 0-1 VDC output.
Sensor type1000 ohm platinum RTD
Measuring range-50 to 50°C (calibrated)
Accuracy±0.3°C at 0°C
Time constant42 seconds with Model 43408 aspirated shield
Output0-1 VDC
Power required8-24 VDC, 5 mA
41342V photo

Model 44203 Temperature sensor.

The Temperature Sensor incorporates the YSI 44203® Thermilinear network, consisting of resistors and precision thermistors that produce an output voltage linear with temperature. The thermistor network is embedded in a stainless steel tube with epoxy resin. The sensor can be used outside the specified temperature range with reduced accuracy.
Sensor typeThermilinear network consisting of resistors and precision thermistors
Measuring range-30 to 50°C (calibrated)
Accuracy±0.12°C at -30°C
±0.07°C at 11°C
±0.02°C at 50°C
(±0.15°C thermistor absolute accuracy and interchangeability)
Download PDF Brochure
Manufacturer
Inteltronics Instrumentation / YSI

Model 41002 Gill 6-plate radiation shield.

R.M. Young
The Model 41002 Gill Multi-Plate Radiation Shield protects temperature and relative humidity sensors from error-producing solar radiation and precipitation. The shield relies on a combination of plate geometry, material and natural ventilation to provide effective shielding.
Sensor typesAccommodates temperature and humidity sensors up to 26 mm diameter
Radiation errorAt 1080 W/m² intensity, dependent on wind speed:
0.4°C RMS at 3 m/s
0.6°C RMS at 2 m/s
1.5°C RMS at 1 m/s
ConstructionUV-stabilised white thermoplastic plates
Aluminium mounting bracket, white powder coated
Stainless steel U-bolt clamp
Dimensions12 cm (4.7 in) diameter
MountingFits vertical pipe 25-50 mm (1-2 in) diameter
41002 photo 1
41002 photo 2

Model 41003 Gill 12-plate radiation shield.

R.M. Young
The Model 41003 Gill Multi-Plate Radiation Shield protects temperature and relative humidity sensors from error-producing solar radiation and precipitation. The shield relies on a combination of plate geometry, material and natural ventilation to provide effective shielding.
Sensor typesAccommodates temperature and humidity sensors up to 26 mm diameter
Radiation errorAt 1080 W/m² intensity, dependent on wind speed:
0.4°C (0.7°F) RMS at 3 m/s (6.7 mph)
0.7°C (1.3°F) RMS at 2 m/s (4.5 mph)
1.5°C (2.7°F) RMS at 1 m/s (2.2 mph)
ConstructionUV-stabilised white thermoplastic plates
Aluminium mounting bracket, white powder coated
Stainless steel U-bolt clamp
Dimensions13 cm (5.1 in) diameter x 26 cm (10.2 in) high
MountingFits vertical pipe 25-50 mm (1-2 in) diameter
41003 photo 1
41003 photo 2

Model 46203 Temperature Humidity Tracker.

R.M. Young
The Temp Tracker is a versatile temperature and relative humidity indicator. Measured values are displayed on the front panel in large illuminated digits: temperature is shown on the left, relative humidity or dewpoint is shown on the right. Maximum and minimum values are saved and can be viewed at any time. The Temp Tracker includes the following useful features: fully-programmable alarms for both channels, alarm relays, calibrated voltage outputs for connection to recording devices, and RS-485 output for interfacing with serial devices.
Temperature Range-50.0 to 150.0°F, -50.0 to 50.0°C
Relative Humidity Range0 to 100%
Display ResolutionTemperature: 0.1°C, 0.1°F
Relative Humidity: 1%
Dewpoint: 1°C, 1°F
Compatible SensorsModel 41372LC (T & RH)
Model 41342LC (T only)
Voltage Outputs0-5 VDC Full Scale for T & RH
Alarm RelaysNormally open contacts for T & RH
Contact rating 5A resistive,
2A inductive @ 250 VAC, 30 VDC
Power Requirement12-30 VDC, 4.5 W
46203 photo